Availability: | |
---|---|
Quantity: | |
LV20
ORR
ORR-LV20-100mm
Applications of LVDT Position Sensor
·TIR measurements
·Hydraulic cylinder position sensing
·Valve position sensing
·Roller gaps alignment
·Brake system inspections
Introduction of LVDT Position Sensor
LVDT is an acronym for Linear Variable Differential Transformer, it is the most widely used inductive position sensor that converts the linear motion into the electrical signal, the output across secondary of this transformer is the differential, therefore, the original signal of LVDT is mV signal.
Special features of LVDT Position Sensor
·Spring loaded, Stroke length up to 100mm(Customizable)
·3-wire voltage output 0-5V or 0-10V; 2-wire current output 4-20mA
·Wide operating Temperature range: -25℃ ~ +85℃
·Non-wear and non-contacting measurement method
·Rugged in hermetically sealed sensors
Applications of LVDT Position Sensor
·TIR measurements
·Hydraulic cylinder position sensing
·Valve position sensing
·Roller gaps alignment
·Brake system inspections
Introduction of LVDT Position Sensor
LVDT is an acronym for Linear Variable Differential Transformer, it is the most widely used inductive position sensor that converts the linear motion into the electrical signal, the output across secondary of this transformer is the differential, therefore, the original signal of LVDT is mV signal.
Special features of LVDT Position Sensor
·Spring loaded, Stroke length up to 100mm(Customizable)
·3-wire voltage output 0-5V or 0-10V; 2-wire current output 4-20mA
·Wide operating Temperature range: -25℃ ~ +85℃
·Non-wear and non-contacting measurement method
·Rugged in hermetically sealed sensors
Specifications of LVDT Position Sensor
Specifications | Technical data |
Stroke length | 5, 10, 15, 25, 50, 100mm(Customizable) |
Input power | 9~28V DC |
Operating current | current of voltage output ≤12mA 2-wire current output of 4~20mA, output: 4~20mA |
Linearity Error | Analog Output: ± 0.25%F.S. ; ± 0.5%F.S.(Optional) Digital Output : ± 0.25%F.S. ; ± 0.1%F.S.(Optional) |
Output signal | 0~5V (9 ~12V DC Input) 0 ~10V (15 ~28V DC Input) 4 ~20mA (2-wire, 15 ~28V DC Input) Digital Output (9 ~28V DC Input Voltage) |
Repeatability error | ≤ 0.1 μ m(Max), 16 bit for Digital Output |
Dynamical property | 5Hz (Max.) |
Operating temp. | -25℃ ~ +85℃ |
Thermal coefficient | Null Position ≤ 0.01%F.S /℃ Sensitivity ≤ 0.025%F.S /℃ |
Specifications of LVDT Position Sensor
Specifications | Technical data |
Stroke length | 5, 10, 15, 25, 50, 100mm(Customizable) |
Input power | 9~28V DC |
Operating current | current of voltage output ≤12mA 2-wire current output of 4~20mA, output: 4~20mA |
Linearity Error | Analog Output: ± 0.25%F.S. ; ± 0.5%F.S.(Optional) Digital Output : ± 0.25%F.S. ; ± 0.1%F.S.(Optional) |
Output signal | 0~5V (9 ~12V DC Input) 0 ~10V (15 ~28V DC Input) 4 ~20mA (2-wire, 15 ~28V DC Input) Digital Output (9 ~28V DC Input Voltage) |
Repeatability error | ≤ 0.1 μ m(Max), 16 bit for Digital Output |
Dynamical property | 5Hz (Max.) |
Operating temp. | -25℃ ~ +85℃ |
Thermal coefficient | Null Position ≤ 0.01%F.S /℃ Sensitivity ≤ 0.025%F.S /℃ |