Availability: | |
---|---|
Quantity: | |
RH
ORR
ORR-RH-M5500
Applications of Magnetostrictive Position Sensor
·Plastics machinery
·Hydraulics machinery industry
·Processing machinery
Introduction of Magnetostrictive Position Sensor
Magnetostrictive position sensor with magnetostrictive technology, bases on principle of pulse variation due to position variation.
Magnetostrictive position sensors are non-contact linear position sensors, magnet ring doesn't contact with thewaveguid, sensing position by magnetic pulse, thus free from wear, no downtimes, a long service life, and high resolution up to 0.001mm.
Special features of Magnetostrictive Position Sensor
·High resolution up to 0.001mm.
·Stroke length up to 5500mm(Customizable)
·Non-wear and non-contacting measurement method
·Interface support analog voltage or current output
Applications of Magnetostrictive Position Sensor
·Plastics machinery
·Hydraulics machinery industry
·Processing machinery
Introduction of Magnetostrictive Position Sensor
Magnetostrictive position sensor with magnetostrictive technology, bases on principle of pulse variation due to position variation.
Magnetostrictive position sensors are non-contact linear position sensors, magnet ring doesn't contact with thewaveguid, sensing position by magnetic pulse, thus free from wear, no downtimes, a long service life, and high resolution up to 0.001mm.
Special features of Magnetostrictive Position Sensor
·High resolution up to 0.001mm.
·Stroke length up to 5500mm(Customizable)
·Non-wear and non-contacting measurement method
·Interface support analog voltage or current output
Basic Specifications of Position Sensor
Specifications | Technical data |
Stroke length | 50~5500 mm (Customizable) |
Resolution | 16 bit D/A or 0.0015%F.S(min.1um) |
Nonlinearity | < ±0.01 %F.S. |
Repeatability | < ±0.001 %F.S. |
Update time | 1ms(F.S≤1m); 2ms(1m<F.S≤2m); 3ms(2m<F.S≤3m |
Output signal | Voltage or current output |
Operating voltage | 24Vdc±20% |
Current consumption | <80mA(depends on stroke length) |
Insulation strength | 500V |
Operating temperature | -40~+85℃ |
Vibration proof | 20g(10... 2000 Hz) |
Shock proof | 50g |
Magnet speed | Any |
Material | Electronic bin: Aluminum, Measuring rod: SUS304 |
Electrical connection | Cable outlet or connector |
IP protection | IP67 |
Basic Specifications of Position Sensor
Specifications | Technical data |
Stroke length | 50~5500 mm (Customizable) |
Resolution | 16 bit D/A or 0.0015%F.S(min.1um) |
Nonlinearity | < ±0.01 %F.S. |
Repeatability | < ±0.001 %F.S. |
Update time | 1ms(F.S≤1m); 2ms(1m<F.S≤2m); 3ms(2m<F.S≤3m |
Output signal | Voltage or current output |
Operating voltage | 24Vdc±20% |
Current consumption | <80mA(depends on stroke length) |
Insulation strength | 500V |
Operating temperature | -40~+85℃ |
Vibration proof | 20g(10... 2000 Hz) |
Shock proof | 50g |
Magnet speed | Any |
Material | Electronic bin: Aluminum, Measuring rod: SUS304 |
Electrical connection | Cable outlet or connector |
IP protection | IP67 |
Installation dimensions
RH series pressure-resistant rodshell, built-in installation design for hydraulic system, pressure-resistant 35MPa continuous, flexible and simple installation mode.Mounting thread form M18×1.5 or M20×1.5 or 3/4"-16UNF-3A.
Note: The measurement Non-usable area shown in the figure indicates that the output value of the sensor in this area is zero or unreliable. The default values of the first and last measurement Non-usable areas of this product are 50.8mm and 63.5mm respectively. The value of the measurement Non-usable area can be appropriately modified according to the needs of customers, please pointed out when ordering.
Installation dimensions
RH series pressure-resistant rodshell, built-in installation design for hydraulic system, pressure-resistant 35MPa continuous, flexible and simple installation mode.Mounting thread form M18×1.5 or M20×1.5 or 3/4"-16UNF-3A.
Note: The measurement Non-usable area shown in the figure indicates that the output value of the sensor in this area is zero or unreliable. The default values of the first and last measurement Non-usable areas of this product are 50.8mm and 63.5mm respectively. The value of the measurement Non-usable area can be appropriately modified according to the needs of customers, please pointed out when ordering.
Note: The forward output of the sensor means that when the magnet ring moves away from the electronic bin, the output value increases and decreases when the magnet ring moves in the reverse direction.
Selection example : RH-M0800-S1-DH02-A01C-S0
Indicates: The ordered product model is RH structural displacement sensor, the measuring range is 800mm, and the mounting thread form is M18×1.5; the diameter of the measuring rod is 10mm, and the material is 304; cable ouelet connection, 2m long PUR orange cable end scattered; 4~20mA current output; no magnet ring display value is the minimum value; single magnet ring; the non-usable area of the first end is 50.8mm, and the non-usable area of the end is 63.5mm.
Note: The forward output of the sensor means that when the magnet ring moves away from the electronic bin, the output value increases and decreases when the magnet ring moves in the reverse direction.
Selection example : RH-M0800-S1-DH02-A01C-S0
Indicates: The ordered product model is RH structural displacement sensor, the measuring range is 800mm, and the mounting thread form is M18×1.5; the diameter of the measuring rod is 10mm, and the material is 304; cable ouelet connection, 2m long PUR orange cable end scattered; 4~20mA current output; no magnet ring display value is the minimum value; single magnet ring; the non-usable area of the first end is 50.8mm, and the non-usable area of the end is 63.5mm.