Applications of Magnetostrictive Position Sensor
·Plastics machinery
·Hydraulics machinery industry
·Processing machinery
Introduction of Magnetostrictive Position Sensor
Magnetostrictive position sensor with magnetostrictive technology, bases on principle of pulse variation due to position variation.
Magnetostrictive position sensors are non-contact linear position sensors, magnet ring doesn't contact with thewaveguid, sensing position by magnetic pulse, thus free from wear, no downtimes, a long service life, and high resolution up to 0.001mm.
Special features of Magnetostrictive Position Sensor
·High resolution up to 0.001mm.
·Stroke length up to 5500mm(Customizable)
·Non-wear and non-contacting measurement method
·CANBus output
Applications of Magnetostrictive Position Sensor
·Plastics machinery
·Hydraulics machinery industry
·Processing machinery
Introduction of Magnetostrictive Position Sensor
Magnetostrictive position sensor with magnetostrictive technology, bases on principle of pulse variation due to position variation.
Magnetostrictive position sensors are non-contact linear position sensors, magnet ring doesn't contact with thewaveguid, sensing position by magnetic pulse, thus free from wear, no downtimes, a long service life, and high resolution up to 0.001mm.
Special features of Magnetostrictive Position Sensor
·High resolution up to 0.001mm.
·Stroke length up to 5500mm(Customizable)
·Non-wear and non-contacting measurement method
·CANBus output
Basic Specifications of Position Sensor
Specifications | Technical data |
Stroke length | 25~5500 mm (Customizable) |
Resolution | 0.1/0.5 / 1 / 2 / 5 / 10 / 20 / 40/ 50 / 100 μm |
Nonlinearity | <±0.01% of full scale, minimum ±50μm |
Repeatability | <±0.001% of full scale, minimum ±1μm |
Interface | CANBus System Protocol, IS0DIS11898 |
CANopen | CIA Standard DS-301V3.0 Encoder Profile DS-406V3.1 |
Operating voltage | 24Vdc±20% |
Current consumption | <80mA(depends on stroke length) |
Insulation strength | 500V |
Operating temperature | -40~+85℃ |
Vibration proof | 20g(10... 2000 Hz) |
Shock proof | 50g |
Magnet speed | Any |
Material | Electronic bin: Aluminum, Measuring rod: SUS304 |
Electrical connection | Cable outlet or connector |
IP protection | IP67 |
Basic Specifications of Position Sensor
Specifications | Technical data |
Stroke length | 25~5500 mm (Customizable) |
Resolution | 0.1/0.5 / 1 / 2 / 5 / 10 / 20 / 40/ 50 / 100 μm |
Nonlinearity | <±0.01% of full scale, minimum ±50μm |
Repeatability | <±0.001% of full scale, minimum ±1μm |
Interface | CANBus System Protocol, IS0DIS11898 |
CANopen | CIA Standard DS-301V3.0 Encoder Profile DS-406V3.1 |
Operating voltage | 24Vdc±20% |
Current consumption | <80mA(depends on stroke length) |
Insulation strength | 500V |
Operating temperature | -40~+85℃ |
Vibration proof | 20g(10... 2000 Hz) |
Shock proof | 50g |
Magnet speed | Any |
Material | Electronic bin: Aluminum, Measuring rod: SUS304 |
Electrical connection | Cable outlet or connector |
IP protection | IP67 |
Installation dimensions
RP Series aluminum profile provides flexible and simple external installation mode, which is suitable for stroke or position detection of linear motion mechanism, and can also be used for external position detection of hydraulic cylinder.
Note: The measurement Non-usable area shown in the figure indicates that the output value of the sensor in this area is zero or unreliable. The default value of the measurement Non-usable area at the head and end is 28mm and 66mm respectively. The value of the measurement Non-usable area can be modified appropriately according to the customer's needs, please pointed out when ordering.
Installation dimensions
RP Series aluminum profile provides flexible and simple external installation mode, which is suitable for stroke or position detection of linear motion mechanism, and can also be used for external position detection of hydraulic cylinder.
Note: The measurement Non-usable area shown in the figure indicates that the output value of the sensor in this area is zero or unreliable. The default value of the measurement Non-usable area at the head and end is 28mm and 66mm respectively. The value of the measurement Non-usable area can be modified appropriately according to the customer's needs, please pointed out when ordering.
Note: The forward output of the sensor means that when the magnet ring moves away from the electronic bin, the output value increases and decreases when the magnet ring moves in the reverse direction.
Selection example: RP-M0300-S1-PD60-C1171-S0
Indicates:The ordered product model is RP structure displacement sensor,
the measuring range is 300mm, the mounting thread form is M18×1.5 (metric system), the measuring rod diameter is 10mm, the material is 304, One set of 6-pin male connector, the baud is 1000kbit/s, the resolution is 0.001mm, single magnet ring, the Non-usable area at the head is 50.8mm, and the Non-usable area at the end is 63.5mm.
Note: The forward output of the sensor means that when the magnet ring moves away from the electronic bin, the output value increases and decreases when the magnet ring moves in the reverse direction.
Selection example: RP-M0300-S1-PD60-C1171-S0
Indicates:The ordered product model is RP structure displacement sensor,
the measuring range is 300mm, the mounting thread form is M18×1.5 (metric system), the measuring rod diameter is 10mm, the material is 304, One set of 6-pin male connector, the baud is 1000kbit/s, the resolution is 0.001mm, single magnet ring, the Non-usable area at the head is 50.8mm, and the Non-usable area at the end is 63.5mm.