Availability: | |
---|---|
Quantity: | |
SP150F
ORR
ORR-SP150F-500kg
Applications of Load Cell
·Scale manufacturers (platform scales)
·Medicine (weighing hospital patients)
·Building industry (weighing materials, power shovels)
Introduction of Load Cell
SP150A single point load cells are perfectly suited for use with any type of tank, batching or platform scales as well as for level monitoring - and are used by market leaders. Precise measurement results up to accuracy class C3 per OIML R60. The particularly robust SP150A single point load cells are available in standard dimensions and can be easily integrated and quickly adapted to the required maximum capacities ranging from 30 kg to 300 kg(Customizable).
Special features of Load Cell
Single point type, low profile
Stainless steel materials
Industry standard size is suitable for implementation in many applications
Compensated off-center load error
Individually configurable with different cable lengths and signal outputs
Applications of Load Cell
·Scale manufacturers (platform scales)
·Medicine (weighing hospital patients)
·Building industry (weighing materials, power shovels)
Introduction of Load Cell
SP150A single point load cells are perfectly suited for use with any type of tank, batching or platform scales as well as for level monitoring - and are used by market leaders. Precise measurement results up to accuracy class C3 per OIML R60. The particularly robust SP150A single point load cells are available in standard dimensions and can be easily integrated and quickly adapted to the required maximum capacities ranging from 30 kg to 300 kg(Customizable).
Special features of Load Cell
Single point type, low profile
Stainless steel materials
Industry standard size is suitable for implementation in many applications
Compensated off-center load error
Individually configurable with different cable lengths and signal outputs
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 410±20Ω
Output resistance: 350±5Ω
Insulation resistance: 2000MΩ
Load Cell construction
Stainless steel
Specifications | Technical data |
Rated capacity | 60、100、200、350、500 (Customizable) |
Output sensitivity | 2.0±0.2 mV/V |
Non-linearity | ≤±0.015 %F.S. |
Hystersis | ≤±0.01 %F.S. |
Repeatability | ≤±0.02 %F.S. |
Creep | ±0.02 %F.S./30min |
Temperature effect on output | ±0.02 %F.S./10℃ |
Temperature effect on zero | ±0.02 %F.S./10℃ |
Input resistance | 410±20 Ω |
Output resistance | 350±5 Ω |
Zero output | <±2 %F.S. |
Insulation resistance | ≥2000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 200 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 15 Vdc |
Material | Stainless steel |
IP protection | IP65 |
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 410±20Ω
Output resistance: 350±5Ω
Insulation resistance: 2000MΩ
Load Cell construction
Stainless steel
Specifications | Technical data |
Rated capacity | 60、100、200、350、500 (Customizable) |
Output sensitivity | 2.0±0.2 mV/V |
Non-linearity | ≤±0.015 %F.S. |
Hystersis | ≤±0.01 %F.S. |
Repeatability | ≤±0.02 %F.S. |
Creep | ±0.02 %F.S./30min |
Temperature effect on output | ±0.02 %F.S./10℃ |
Temperature effect on zero | ±0.02 %F.S./10℃ |
Input resistance | 410±20 Ω |
Output resistance | 350±5 Ω |
Zero output | <±2 %F.S. |
Insulation resistance | ≥2000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 200 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 15 Vdc |
Material | Stainless steel |
IP protection | IP65 |
Load Cell dimensions:
Load Cell dimensions:
Load Cell order guide:
Load Cell order guide: