LBFF1
ORR
ORR-LBFF1-1760kg
Applications of Load Cell
·Scale manufacturers (platform scales, legal-for-trade scales)
·Medicine (weighing hospital patients)
·Building industry (weighing materials, power shovels)
·Agriculture (automatic feeders)
·Public sector (weighing garbage)
·Quality assurance
Introduction of Load Cell
Cantilever Beam load cell is ideal for use in static and quasi-static weighing tasks; for instance, for the gravimetric level measurement of suspended tanks as well as for conveyor, batching, and hybrid scales. It is available in seven maximum capacities, which range from 220 to 1760kg, thus covering a very broad range, the product is widely used for various scale, industrial weighing system.
Special features of Load Cell
·Cantilever beam design, compression force measurement
·Wide measuring range up to 1760kg
·Excellent overload capacity
·High accuracy, water-proof, anti-corrosion
Applications of Load Cell
·Scale manufacturers (platform scales, legal-for-trade scales)
·Medicine (weighing hospital patients)
·Building industry (weighing materials, power shovels)
·Agriculture (automatic feeders)
·Public sector (weighing garbage)
·Quality assurance
Introduction of Load Cell
Cantilever Beam load cell is ideal for use in static and quasi-static weighing tasks; for instance, for the gravimetric level measurement of suspended tanks as well as for conveyor, batching, and hybrid scales. It is available in seven maximum capacities, which range from 220 to 1760kg, thus covering a very broad range, the product is widely used for various scale, industrial weighing system.
Special features of Load Cell
·Cantilever beam design, compression force measurement
·Wide measuring range up to 1760kg
·Excellent overload capacity
·High accuracy, water-proof, anti-corrosion
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 380±20Ω
Output resistance: 350±5Ω
Insulation resistance: 5000MΩ
Load Cell construction
Stainless steel
Specifications | Technical data |
Rated capacity | 220、 550、 1100、 1760 kg |
Output sensitivity | 2.0±0.002 mV/V |
Non-linearity | ≤±0.0180 %F.S. |
Hystersis | ≤±0.0170 %F.S. |
Repeatability | ≤±0.01 %F.S. |
Creep | ±0.0166 %F.S./30min |
Temperature effect on output | ±0.0170 %F.S./10℃ |
Temperature effect on zero | ±0.0170 %F.S./10℃ |
Input resistance | 380±10 Ω |
Output resistance | 350±3 Ω |
Zero output | <±1 %F.S. |
Insulation resistance | ≥5000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 300 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 15 Vdc |
Material | Stainless steel |
IP protection | IP67 |
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 380±20Ω
Output resistance: 350±5Ω
Insulation resistance: 5000MΩ
Load Cell construction
Stainless steel
Specifications | Technical data |
Rated capacity | 220、 550、 1100、 1760 kg |
Output sensitivity | 2.0±0.002 mV/V |
Non-linearity | ≤±0.0180 %F.S. |
Hystersis | ≤±0.0170 %F.S. |
Repeatability | ≤±0.01 %F.S. |
Creep | ±0.0166 %F.S./30min |
Temperature effect on output | ±0.0170 %F.S./10℃ |
Temperature effect on zero | ±0.0170 %F.S./10℃ |
Input resistance | 380±10 Ω |
Output resistance | 350±3 Ω |
Zero output | <±1 %F.S. |
Insulation resistance | ≥5000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 300 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 15 Vdc |
Material | Stainless steel |
IP protection | IP67 |
Load Cell dimensions:
Load Cell dimensions:
Load Cell order guide: